Light the room, not the ceiling
The number of downlights comes from how much light the room needs, not from how many holes look tidy. Light is measured in lux, lumens per square metre arriving where you need it. A living room is comfortable at about 150 lux, a kitchen needs 300 because people use knives in it, and a bedroom is fine at 100. Multiply the room area by the target, allow for the light that is lost to walls and ceilings, and divide by what each fitting puts out.
downlights = room area × lux ÷ (lumens per fitting × 0.6)
| Room | Target | 4 × 3 m | 5 × 4 m | 7 × 5 m |
|---|---|---|---|---|
| Bedroom | 100 lux | 3 | 5 | 8 |
| Living room | 150 lux | 4 | 7 | 11 |
| Bathroom, laundry | 250 lux | 7 | 11 | 19 |
| Kitchen | 300 lux | 8 | 13 | 22 |
800 lumen fittings, average room surfaces.
Setting them out
Even spacing gives even light. Divide the room into a grid, put a light in the middle of each cell, and the first row lands half a spacing in from the wall. With a 2.4 metre ceiling, spacings of 1.2 to 2 metres work; closer than that and the ceiling looks like a runway, wider and the floor shows pools of light. Then move individual lights for the things a grid ignores: off the ceiling joists, away from the fan, centred on the kitchen bench rather than the walkway behind it, and never directly above where a head sits on a couch or pillow.
The watts limit
The National Construction Code caps the installed lighting in a house at 5 watts per square metre, with lower allowances for verandahs and garages. It was written when a downlight was a 50 watt halogen and a living room could burn 600 watts. With 9 watt LEDs a normally lit room sits around 3 watts per square metre, so the limit only bites when someone specifies a very bright kitchen or leaves old fittings in place. The calculator shows the figure so you can see the margin.
Worked example
A 5 by 4 metre living room, 20 m², at 150 lux needs 3,000 lumens delivered. With average surfaces each 800 lumen fitting delivers about 480, so 3,000 ÷ 480 = 6.25, rounded up to 7. An even grid is 2 rows of 4, eight fittings at 1.25 m along the length and 2.0 m across, starting 0.63 m and 1.0 m from the walls. That delivers 192 lux and uses 72 watts, 3.6 W/m², inside the limit.
Common questions
How many per square metre?
About one per 3 m² in a living room, one per 4 m² in a bedroom, one per 1.5 m² in a kitchen.
How far apart?
1.2 to 2 m with a 2.4 m ceiling, and half that in from the walls.
How many lumens for a room?
Area × lux, then about 1.7 times that from the lamps to allow for losses.
Is there a legal limit?
5 W/m² indoors for a house under the National Construction Code.
A planning estimate. Fixed wiring must be installed by a licensed electrician, and fittings must suit the ceiling insulation and any wet-area zones.